Additional Details
Built-in SoftPLC Built-in Categ, y-2 RFI Filter Built-in 24Vdc Power supply max 150 mA Built-in RS-485 Modbus RTU/BACnet communication Dynamic Braking Transist, Included
Agency Listing
UL 61800-5-1, UL 840, EN 61800-5-1, EN 50178, EN 60204-1, EN 60146, EN 61800-2, EN 61800-3, EN 55011, CISPR 11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 60529, UL 50
Ambient Temperature Range
-10 to 40 °C, 14 to 104 °F
Automation Option Cards
CFW500-IOS, CFW500-IOD, CFW500-IOAD, CFW500-IOR-B, CFW500-ENC, CFW500-CUSB, CFW500-CRS232, CFW500-CRS485-B, CFW500-CCAN, CFW500-CPDP, CFW500-CPDP2, CFW500-CEMB-TCP, CFW500-CEPN-IO, CFW500-CETH-IP, CFW500-CETH2, CFW500-SFY2
Backup Option Cards
CFW500-MMF
Communications Option Cards
Modbus RTU, BACnet, USB, RS232, RS485, CANopen, DeviceNet, Profibus DP, Modbus TCP, ProfiNet I/O, EtherNet IP
Compatible Accessories
['CFW500-HMIR', 'HMI-01', 'CFW500-RHMIF', 'CFW500-CCHMIR01M', 'MW500-CCHMIR02M', 'MW500-KAIM-A70', 'MW500-KCFA-CL56', 'MW500-KCFB-CL56', 'MW500-KCFC-CL70/110']
Configurable Digital Inputs Outputs
4 In, 1 Out
Drive Output Voltage
0-240 VAC
Drive Supply Voltage
200/240 V ac
Drive Type
Variable Frequency Drive (VFD)
Enclosure Rating
IP66, NEMA 4X
Enclosure Type
NEMA 4X
Encoder Connection
Pluggable Terminal Block
Feedback Option Cards
CFW500-ENC
Feedback Type
Sensorless Vector
Horsepower Rating Heavy Duty
1/2 hp
Horsepower Rating Normal Duty
1/2 hp
I/O Option Cards
CFW500-IOS, CFW500-IOD, CFW500-IOAD, CFW500-IOR-B
Input Frequency Rating
48 to 62 Hz
Keypad / Display
Optional
Manufacturer Catalog Number
MW500A02P1S2DB66C2A70G2
Max Ambient Temperature
40 °C, 104 °F
Min Ambient Temperature
-10 °C, 14 °F
Motor Phase
3
Mounting Type
Wall Mounted
Number Of Analog Inputs
1
Number Of Analog Outputs
1
Number Of Digital Inputs
4
Number Of Digital Outputs
2
Number Of Digital Outputs Relays
1
Number Of Input Phases
1
Number Of Option Slots
1
Number Of Output Phases
3
Number of Relays
1
Number Of Safety Inputs Sto
0
Operating Temperature Range
14 to 104 °F, -10 to 40 °C
Operation Mode
Scalar, Vector Control, VVW PM
Output Current Heavy Duty
2.1 A
Output Current Normal Duty
2.1 A
Peak Current
3.15 A
Peak Current Heavy Duty
3.15 A
Peak Current Normal Duty
3.15 A
PI / PID Controller
Integrated
PLC Functions
Built-in SoftPLC
Product Type
AC Variable Frequency & Servo Drives
Pulse Train Input Capability
No
Pulse Train Output Capability
No
Remote Keypad
Optional
Safety Option Cards
Safe Torque Off (STO), Safe Stop 1 (SS1)
Serial Communication Device Net
Optional
Serial Communication Interbus S
Optional
Serial Communication Modbus
Modbus RTU
Serial Communication Onboard
Modbus RTU, BACnet
Serial Communication Options
Modbus RTU, CANopen, DeviceNet, Profibus DP, EtherNet/IP, Modbus TCP, PROFINET IO, USB, RS485, RS232
Serial Communication Profibus Dp
Optional
Series
MW500
Standard Operating Temperature Range
14 to 104 °F
Standards Met
UL, EN, IEC, CISPR
Trade / Brand Name
MW500
Typical Application
Pumps, Fans, Ventilators, Blowers, Conveyors, Rollout tables, Mixers, Blenders, Commercial dryers, Extruders, General machinery, Agitators