Specifications
Details
- Additional DetailsSafe T, que Off STO, Built-In Modbus RTU, Onboard PLC Functionality, Conf, mal Coated Boards, Dynamic Braking Transist
- Agency ListingCE, UL, cUL, RoHS, TUV, UKCA, EAC, RCM
- Ambient Temperature Range40 °C, 104 °F
- Automation Option CardsSI-PROFIBUS, SI-DeviceNet, SI-CANopen, SI-PROFINET V2, SI-Ethernet, SI-BACnet IP, SI-EtherCAT, SI-POWERLINK, SI-Interbus, SI-I/O, SI-Encoder V2
- Backup Option CardsAI-Backup adaptor
- Chk Input Line Choke Or Dc Link ChkInternal Input Choke
- Communications Option CardsSI-PROFIBUS, SI-DeviceNet, SI-CANopen, SI-PROFINET V2, SI-Ethernet, SI-BACnet IP, SI-EtherCAT, SI-POWERLINK, SI-Interbus
- Compatible Accessories['AI-485 adaptor, AI-Backup adaptor, Remote-Keypad, Remote-Keypad RTC, KI-Keypad Plus, CT USB Comms cable, External EMC filter, Braking resistor']
- Configurable Digital Inputs Outputs5 In, 1 Out
- Drive Output Voltage0-240 VAC
- Drive Supply Voltage200/240 V ac
- Enclosure RatingIP20, NEMA 1
- Enclosure TypeIP20, NEMA 1
- Feedback Option CardsSI-Encoder V2
- Feedback TypeSensorless Vector
- I/O Option CardsSI-I/O
- Input Frequency Rating50 to 60 Hz
- Keypad / DisplayDigital LED
- Manufacturer Catalog NumberC300-06200440A10101AB100
- Motor Phase3
- Mounting TypeSurface, Through-Panel, Tile Mounted
- Number Of Analog Inputs2
- Number Of Analog Outputs1
- Number Of Digital Inputs5
- Number Of Digital Outputs1
- Number Of Digital Outputs Relays1
- Number Of Input Phases3
- Number Of Option Slots1
- Number Of Output Phases3
- Number of Relays1
- Number Of Safety Inputs Sto2
- Operating Temperature Range104 °F, 40 °C
- Operation ModeSensorless closed-loop permanent magnet motor control, Open loop induction motor control
- Output Current Heavy Duty44 A
- Peak Current Normal Duty440 A
- PI / PID ControllerIntegrated
- PLC FunctionsIntegrated Logic, Timers and Counters, Arithmetic Operations, Real-Time Clock (RTC)
- Product TypeAC Variable Frequency & Servo Drives
- Pulse Train Input CapabilityYes
- Pulse Train Output CapabilityYes
- Remote KeypadOptional
- Safety Option CardsSI-Safety
- Serial Communication Device NetOptional
- Serial Communication Interbus SOptional
- Serial Communication ModbusModbus RTU
- Serial Communication OnboardModbus RTU
- Serial Communication OptionsModbus RTU, EtherNet/IP, PROFINET, DeviceNet, CANopen, BACnet IP, PROFIBUS DP, EtherCAT, POWERLINK
- Serial Communication Profibus DpOptional
- SeriesCommander C300
- Standard Operating Temperature Range104 °F
- Standards MetEN 61800-5-1, EN 61800-3, EN 61000-6-2, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, EN 61000-3-12, EN ISO 13849-1, EN 62061, IEC 61508, UL, cUL, RoHS, REACH
- Trade / Brand NameCommander C300
- Typical ApplicationGeneral Purpose
Overview
Mfr description
C300-06200440A10101AB100 C300-06200440A1