Specifications
Dimensions
- Port 1 Size/TypeG 1/2
- Port 2 Size/TypeG 1/2
- Port SizeG 1/2
- Weight3.88 oz, 110.00 g
Details
- Additional DetailsModel Code Description, VD2B.1/-V, Type deg F Indication, Visual, Red, Green Band Automatic Reset, Trip Pressure Range Tolerance, ±10 %, Note for Trip Pressure Range, Standard, for use on return line filters, Degree deg F Protection, Protection Class to DIN 40050, Medium, Mineral Oil, Maximum Torque, 74 lbsft, 100 Nm, BUn, EA, Short Description, Visual pop-up with automatic reset, Division, HYDRAULIC AND LUBE FILTERS, Product Group Family, INDICATORS-DIFFERENTIAL, Product, MISCELLANEOUS H and L, Supplementary Details, Fluorocarbon elastomer (FKM), suitable for phosphate esters (HFD-R) and biodegradable oils (must be specified for type GW). Nitrile (NBR) is standard. Ethylene propylene (EPDM, code EPR) available upon request.
- Filter TypeDifferential Pressure Clogging Indicator
- Fluid CompMineral Oil
- Indicator Trip Pressure29 psi, 2 bar
- Indicator TypeVisual, Red, Green Band Automatic Reset
- Max Operating Temperature212 °F
- Maximum Operating Pressure420 bar, 6000 psi
- Seal MaterialNitrile
- SeriesVD
- Standards MetATEX, UL, CSA US, DIN 40050
- Trip Pressure29 psi, 2 bar
Help us improve this product
Customers Also Bought
Compare Up to 3 ItemsCompare Items (0/3)