Additional Details
Safe T, que Off STO Onboard PLC Functionality NV Media Card f, parameter copying and data st, age Dual channel Safe T, que Off STO input
Agency Listing
cULus File E171230, TUV #01/205/5387.00/14
Automation Option Cards
SI-PROFIBUS, SI-DeviceNet, SI-CANopen, SI-PROFINET V2, SI-Ethernet, SI-EtherCAT, SI-I/O
Backup Option Cards
AI-BACKUP-ADAPTOR, AI-SMART-ADAPTOR, CTSD8GB
Chk Input Line Choke Or Dc Link Chk
Requires External Input Choke
Communications Option Cards
AI-485-ADAPTOR, CI-485-ADAPTOR, SI-CANOPEN, SI-DEVICENET, SI-ETHERNET, SI-ETHERCAT, SI-PROFINET-V2, SI-PROFIBUS
Compatible Accessories
Backup, Communications, I/O
Configurable Digital Inputs Outputs
2
Drive Output Voltage
0-400 VAC
Drive Supply Voltage
200/240 V ac
Drive Type
Sensorless Vector
Enclosure Rating
IP 20
Enclosure Type
IP20
Encoder Connection
Screw Terminal
Feedback Option Cards
SI-I/O
Feedback Type
Open Loop
Horsepower Rating Heavy Duty
60 hp
Horsepower Rating Normal Duty
75 hp
I/O Option Cards
SI-I/O
Input Frequency Rating
50/60 Hz
Keypad / Display
Option CI-Keypad LCD
Manufacturer Catalog Number
M400-09201760E10101AN100
Motor Phase
3
Mounting Type
Surface, Through-panel
Number Of Analog Inputs
2
Number Of Analog Outputs
2
Number Of Digital Inputs
5
Number Of Digital Outputs
0
Number Of Digital Outputs Relays
1
Number Of Input Phases
3
Number Of Option Slots
1
Number Of Output Phases
3
Number of Relays
1
Number Of Safety Inputs Sto
2
Operating Temperature Range
104 °F, 40 °C
Operation Mode
Frequency Control, Open Loop Vector Control, Rotor Flux Control
Output Current Heavy Duty
176 A
Output Current Normal Duty
216 A
Peak Current
264 A
Peak Current Heavy Duty
308 A
Peak Current Normal Duty
237.6 A
PI / PID Controller
PID Controller
PLC Functions
Onboard PLC
Product Type
AC Variable Frequency & Servo Drives
Pulse Train Input Capability
Yes
Pulse Train Output Capability
Yes
Remote Keypad
Remote-Keypad, Remote-Keypad-RTC
Safety Option Cards
Safe Torque Off (STO)
Serial Communication Device Net
Optional
Serial Communication Interbus S
Optional
Serial Communication Modbus
Modbus RTU
Serial Communication Onboard
Modbus RTU
Serial Communication Options
CANOpen, DeviceNet, EtherCAT, EtherNet/IP, Modbus RTU, Modbus TCP/IP, PROFIBUS DP, PROFINET RT
Serial Communication Profibus Dp
Optional With Adapter
Series
Unidrive M
Standard Operating Temperature Range
-4 to +104 °F
Standards Met
UL508C, EN61000-3-2:2006, EN61000-3-3:2008, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61000-6-1, EN61000-6-2, EN61800-3:2004, EN61800-3:2004, EN61800-5-1:2007, EN61000-6-2:2005, EN61000-6-4:2007
Trade / Brand Name
Unidrive M400
Typical Application
Fans, Pumps, Conveyors, Compressors
Warranty
2 Years